0
  • No products in the cart.

ONDULEUR SOLAIRE HORS RÉSEAU HYBRIDE 3.5KVA/24V (AVEC TRANSFORMATEUR)

In stock

 516

code produit: SSP3115C

poids: 31.00kg

Dimensions: 345.00mm x 482.00mm x 190.00mm


Compare

Description

ONDULEUR SOLAIRE HORS RÉSEAU HYBRIDE 3.5KVA/24V (AVEC TRANSFORMATEUR)

CONTRLEUR DE CHARGE SOLAIRE 60A MPPT INTÉGRÉ.
SORTIE D’ONDE SINUSODE PURE.
LE COURANT DE CHARGE EST JUSQU’À 85 AMP.
LE FACTEUR DE PUISSANCE DE SORTIE EST DE 0.9-1.
BIEN ACCEPTER LA SORTIE DU GÉNÉRATEUR.
FONCTIONNEMENT ENTIÈREMENT AUTOMATIQUE ET SILENCIEUX.
TRANSFERT AUTOMATIQUE ENTRE LES MODES BATTERIE ET ​​LIGNE.
LE CONTRLE PAR MICROPROCESSEUR GARANTIT UNE HAUTE FIABILITÉ.
FONCTION DE TÉLÉCOMMANDE.
CONTRLE DE CHARGE INTELLIGENT À QUATRE ÉTAPES POUR LE TEMPS DE RECHARGE.
FONCTION DE RÉGULATION DE TENSION DE BYPASS ET DE BYPASS.
AVEC FONCTION AVR (EN OPTION).
NIVEAU DE PRIORITÉ DE LA SORTIE RESEAU/SOLAIRE AU CHOIX DU CLIENT.
RESEAU/SOLAR/ RESEAU & CHARGE SOLAIRE TROIS MODES DE PRIORITES AU CHOIX DU CLIENT.
LE TYPE DE BATTERIE PEUT CHOISIR DE 0-9.
PROTECTION CONTRE LES SURCHARGES ET LES COURTS-CIRCUITS.
CONCEPTION DU TRANSFORMATEUR FORTE RÉSISTANCE AUX IMPACTS

Caractéristiques
données techniques
Informations requises

MODEL SPS3115C 1-10KW
1kW 1.5kW 2kW 3kW 4kW 5kW 6kW 8kW 10kW
Input wave form Sine wave (utility or generator)
Normal voltage 120VAC(option)    230VAC
Low voltage re trip 90V±4% & 184V/154V±4%
Low voltage re engage 100V±4% & 194V/164V±4%
High voltage re trip 140V±4% & 253V±4%
High voltage re engage 135V±4% & 243V±4%
Normal input frequency 50Hz/ 60Hz (auto detection)
Frequency range 47Hz~65Hz
Output Wave form (Bypass mode)same as input
Over-Load Protection Circuit breaker
Short circuit Protection Circuit breaker
Efficiency on line transfer mode undefined95%
Line transfer time 10ms Typical
Bypass without battery connected Yes
Inverter output
Output wave form Pure sine wave
Output continuos power watts 1000 1500 2000 3000 4000 5000 6000 8000 10000
Surge ratings 3000 4500 6000 9000 12000 15000 18000 24000 30000
Power factor 0.9-1.0
Nominal Output Voltage rms 120VAC(option) 230VAC
Output Voltage regulation +/- 10%rms
Output frequency 50Hz ± 0.3Hz or 60Hz ± 0.3Hz
Short circuit protection Yes,fault after 1 secs
Inverter input
Nominal input voltage 24V/48V 48V
Minimum start voltage 20V/40V 40V
Low battery alarm 21V/42V 42V
Low battery trip 20V/40V 40V
High voltage alarm 32V/64V 64V
Charger
Output voltage Dependent on battery type
Charge current 10-85A MAX 70A 85A
Battery initial voltage for start up 0-15.7v for 12v(*2 for 24v;*4 for 48v)
Over charge protection 15.7v for 12v(*2 for 24v;*4 for 48v)
Solar Charger
MPPT Range@Operating Voltage 30-115VDC/60-115VDC
Maximum PV Array Open Circuit Voltage 145VDC
Maximum Charging Current 60A
Maximum Effciency >96%

Additional information

Weight 31 kg
Dimensions 345 × 482 × 190 mm

3.5KVA -24V HYBRID OFFGRID SOLAR INVERTER - SSP 3115C TECHNICAL SPECIFICATIONS

Download

Login Account

Already a Elektron Customer?

Invaild email address.

6 or more characters, letters and numbers. Must contain at least one number.

Your information will nerver be shared with any third party.